The implementation standard of the vulcanizator is |
ASTMD5289-95 ISO6502-1999 (E) GB/T16584-1996 |
Temperature measurement range |
Room temperature--200ºC |
Temperature measurement accuracy |
100--200ºC,≤±0.1ºC |
Temperature control stability |
100--200ºC,≤±0.1ºC |
Predetermined area |
0--200ºC; set minimum unit: 0.1ºC |
Temperature display range |
0--200ºC; Display resolution: 0.1ºC |
Set the time range; |
0--200 minutes |
Set the minimum unit |
1 minute |
Automatic range switching |
Automatically increase according to the actual torque |
Power supply |
50HZ, ~220V±10%, 50±1Hz, must be well grounded |
Compressed air |
0.32Mpa controlled by pneumatic regulating valve |
Swing frequency |
100 times/min (about 1.7HZ) |
Ambient temperature |
Normal temperature--40ºC, relative humidity less than 80%, no corrosive gas in the air |
Quality |
≈250kg |
Power |
2KW |
Dimensions |
680×630×1100(mm) |