Control System |
Programmable Controller ( PLc ) |
Screen settings and display data |
Parameter monitoring, current preset, angle setting, speed preset, count setting, station selection,
alarm indication and character prompt, etc. |
Test station |
2 stations; the program can set the experiment of single station or any station by itself |
Test rate |
Can be set and intelligently adjusted 5~60 times/min ( r . p . m ) |
Test bending rotation angle |
Can be set and intelligently adjusted (5720 degree test angle can be preset) |
Counter |
0~9999999 times can be preset, with power failure memory function |
Weight and material |
2 sets of 20N, 25N, 50N, 75N, 100N weights each, the weight material is sus304# stainless steel |
Optional test resistive/inductive load |
0-60A can be adjusted manually |
Test voltage |
ACo ~250v continuously adjustable, 31/2LED digital display, accuracy: 0.5 class |
Test current |
ACo ~60A continuously adjustable, 31/2LED digital display, accuracy: 0.5 class |
An external power supply can be used to conduct experiments on the connection parts of electrical finished products;
(excluding external frequency conversion power supply, outsourcing is required) |
Equipped with an intelligent ammeter, which can set the upper and lower limit numbers, which is convenient for judging the short circuit,
open circuit and adhesion of the power line under test, and can cut off the counter of the current station; |
External band pointer showing bend angle |
1 set of fixing brackets with wires, easy to install |
Power supply voltage: AC220V±5%, 50Hz10A |