technical parameter |
|
temperature range |
60℃~+150℃ |
temperature fluctuation |
≤±0.5℃ (at normal pressure, no load, constant state) |
temperature uniformity |
≤2℃ (at normal pressure, no load, constant state) |
temperature deviation |
≤±2℃ (at normal pressure, no load, constant state) |
Heating and cooling rate |
Air temperature: -60℃-+150℃, the whole process average ≥1℃/min, normal
pressure, with load of 10kg aluminum ingot; |
|
Air temperature: +150℃-60℃, the whole process average ≥1℃/min,
normal pressure, with a load of 10g aluminum ingot |
pressure range |
normal pressure~0.5kPa (common pressure 62kPa, simulated altitude 4km) |
buck rate |
normal pressure~1.0kPa depressurization time≤30min |
|
pressure recovery rate: ≤10.0kPa/min |
fast buck |
rapid decompression: 75.2kPa--18.8 kPa ≤15s |
pressure deviation |
when the pressure is ≥40KPa: ≤±2KPa |
|
when the pressure is 4KPa~40KPa: ≤±5% |
|
when the pressure is ≤4KPa: ≤±0.1KPa |
rate of change of air pressure |
K15kPa/min (adjustable) |
fulfill the standard |
CB/T 2423.212008 Basic environmental test procedures for electrical and electronic
products Test method for low air pressure |
acceptance Criteria |
CB/T5170 |
CB/T5170 |